• Matisse R5

    (v 1.1) Safety and usage cautions Before installing our products, we recommend you to consult the section about safety and usage cautions at the link below. Application areas The Matisse R5 is the electronic brain that controls DMG’s most innovative visual & media systems A) – Matisse Multimedia (dimensions: 7″…

  • Push-button B7 Maxxi

    (v 1.0) Safety and usage cautions Before installing our products, we recommend you to consult the section about safety and usage cautions at the link below Cut-out Mounting of B7 Maxxi A) – FaceplateB) – Wiring Dismantling of B7 Maxxi Mounting of B7 IP54 version A) – FaceplateB) – O-Ring…

  • Discontinued or not published products on the DIDO website.

    Electric Systems JUNIOR system PITAGORA V3 PLAYBOARD R2 PITAGORA V1 Universal TOC interface CRONOS Visual & Media Systems Giotto V3 D13 (parallels) D33 (parallels) D47 DX3 – DX6 DZ3 Display with multicard system 7-segment and dot matrix serial displays Fixtures Gilda Caprice Danielle SHELL – Water resistant control panel Components…

  • Rope magnetic encoder

    (v 1.0) The new DMG magnetic encoder uses a sensor to detect the rotation and position of a magnet placed on the encoder pulley axle. The pulses generated are received and processed by the lift control panel which calculates the position, direction and speed of the car. Safety and usage…

  • Pitagora 4.0 – Shaft

    Shaft access For systems with encoder counting it is possible to activate the access procedure in the shaft without the system being stopped due to the interruption of the safety chain (opening of the landing doors). It is also helpful in EN81-1 installation. With the lift in normal operation: Access…

  • Pitagora 4.0 – Fire service operation

    The system has the following inputs for firefighters’ operations: Reference standards EN81-72:2015 – Firefighters lift (Europe) The EN 81-72 standard establishes the safety rules for the construction and installation of lifts with particular reference to fire-fighting lifts.• The standard applies to all new installations inside new buildings.• The “Firefighter” Lift…

  • Pitagora 4.0 – Test and measurements

    Procedures for system safety testings and for space-time measuring elevator car movement are described here. The following tests and measures may facilitate controls and tests to be performed before putting the installation in service (EN81-X D) and during the periodic maintenance interventions (EN81-X E). Some measures can be performed only…

  • Pitagora 4.0 – Car / Top of car

    Door command The door command board can command either one or two doors with alternative, selective or passage through opening. Output and inputs are available on the jst connectors on the TOC board and on APPO board (in the controller). The doors can be automatic, semi-automatic or manual: DOOR A…

  • Pitagora 4.0 – Controller

    Motherboard The control board of the Pitagora 4.0 system is based on 32-bit electronic technology and operates all types of electric and hydraulic lifts. Serial and/or parallel connections to pushbutton panels (cabin and floor) may be added. It is particularly suitable for VVVF electrical installations, also those equipped with the…