1. Home
  2. Components
  3. Touchless button

Touchless button

(v 1.2)

To check and download all versions of this guide, go at the following link.

Safety and usage cautions

Before installing our products, we recommend you to consult the section about safety and usage cautions at the link below.

Do not touch the control panel using wet hands or other wet body parts.
Do not install the control panel in a humid enviroment and/or in direct sunlight.
Unintentional activations may happen in the following cases:
• During the cleaning phase.
• If the control panel is not completely dry.

The protective film must be removed before powering the control panel.

Call buttons

–   Datasheet   –

Contacts1 contact (with or without beep)
Power supply12/24 Vdc ± 10% (Not Rectified current!)
Optional power supply EWS.AL224 to supply power up to 20 components (push-buttons or signalations)
Maximum absorption12Vdc: 26mA / 24Vdc: 30 mA
CE certificationElectromagnetic compatibility:
directive 2014-30-EU – EN 120125:2014 and EN 12016:2013
REACH: directive 2011-65-EU
Operating temperature-5 / +50 °C

A) – Optional power supply (strongly recommended)

Wiring with Pitagora 4.0 pre-wired system

Service buttons

–   Datasheet   –

Open door / closed door

Contacts1 contact (with or without beep)
Power supply12/24 Vdc ± 10% (Not Rectified current!)
Optional power supply EWS.AL224 to supply power up to 20 components (push-buttons or signalations)
Maximum absorption12Vdc: 26mA / 24Vdc: 30 mA
CE certificationElectromagnetic compatibility:
directive 2014-30-EU – EN 120125:2014 and EN 12016:2013
REACH: directive 2011-65-EU
Operating temperature-5 / +50 °C

Alarm button (touch mode only)

Contacts2 contacts NC/NO
Power supply12/24 Vdc ± 10% (Not Rectified current!)
Optional power supply EWS.AL224 to supply power up to 20 components (push-buttons or signalation)
Maximum absorption12Vdc: 26mA / 24Vdc: 30 mA
CE certificationElectromagnetic compatibility:
directive 2014-30-EU – EN 120125:2014 and EN 12016:2013
REACH: directive 2011-65-EU
Operating temperature-5 / +50 °C

Wiring with Pitagora 4.0 pre-wired system

Download

ReferenceVersionLink
1.0Download PDF
(English)
Wiring with Pitagora 4.0 pre-wired system1.1
Change of the contact holder module for service buttons1.2 (current version)Download PDF (English)
Updated on 24 Maggio 2024
Was this article helpful?

Related Articles