Protetto: Raffaello M-One
Non è disponibile alcun riassunto in quanto si tratta di un articolo protetto.
Non è disponibile alcun riassunto in quanto si tratta di un articolo protetto.
Once the floor self-learning procedure has been completed and the lift has been set to normal service mode, it is possible to manually adjust the floor stopping accuracy. Two different procedures are available, depending on the type of counting system.1) Magnetic readers counting system2) DMG incremental encoder / Motor encoder…
1) Switch the system into NORMAL service mode Main Menu > Emulation > Configuration > Temporary operations > NO 2) System reset The LED 7 is OFF – There are no active faults.The cabin moves to the lowest floor for a system reset. The red LED 7 is flashing –…
1) Switch the lift into INSPECTION mode 2) Motor Parameter check From the main menu, access the Emulation menu. Main Menu > Emulation > VVVF Advanced GEARED motors Parameters normally pre-set if specified when ordering. VVVF Fuji parameter Description Note P01 – Motor poles Enter the number of motor poles…
Non è disponibile alcun riassunto in quanto si tratta di un articolo protetto.
Using DMG rope magnetic encoder or motor encoder From the main menu, access the Emulation menu. Main Menu > Emulation (1) – Check that the lift is in temporary operations. Main Menu > Emulation > Configuration > Temporary operations > YES (2) – Check that the direction of car movement…
When the Pitagora controller is applied to installations equipped with closed loop gearless machines, comfort and precision can be optimized thus avoiding undesired effects such as rollback (typical of lifts with unbalanced load).The following parameters can be adjusted to achieve optimal setting for your installation. It is suggested to follow…
Non è disponibile alcun riassunto in quanto si tratta di un articolo protetto.
Overview The Pitagora 4.0 System offers two different wiring solutions to connect the landing operating panel to the controller: Serial WiringBased on a single serial connection line, interspersed with shaft units (BDU), this solution is most suitable for new installations and complete modernizations, especially for buildings with a higher number…
What you need Preliminary steps 1) Copy the .bin file to the USB flash drive. It is not necessary to rename the file. 2) With the elevator stopped, open the safety chains by deactivating the “-DIS” switch. 3) Remove the connectors cover by unscrewing the fastening screws. Firmware update instructions…