Call enabling
CABIN
Enables all cabin call buttons simultaneously.
Key location | Type (Position / Extraction) | Input | Contact type |
---|---|---|---|
Cabin | 2P / 1E | DMCPIT >> Call enable | Normally closed |

FLOORS
Enables all floors call buttons simultaneously.
Key location | Type (Position / Extraction) | Input | Contact type |
---|---|---|---|
Floors | 2P / 1E 2P / 2E | BDU >> IN-1 CSITLOPV30 >> KEY | Normally open |


Reset of cabin call requests
Delete all calls
Key location | Type (Position / Extraction) | Input | Contact type |
---|---|---|---|
Cabin | 2P / 1E / Sprin return | DMCPIT >> Call cancel | Normally open |

Cabin calls
Makes a cabin call via key contact, instead of the button.
Key location | Type (Position / Extraction) | Input | Contact type |
---|---|---|---|
Cabin | 2P / 1E / Sprin return | DMCPIT >> Call00…Call27 | Normally open |

Penthouse
Enable the reserved floor, programmable from the controller. Solution for systems with direct access to private houses (or private floors), typically on the top floor of the building.
The COP should include one or more keys (depending on the number of protected floors) to make a call to the ‘Penthouse’ floor, and a button for each protected floor, normally disabled, which is activated only by the associated Pick-up key.
In the LOP of the Penthouse floor, a key-switch should be provided to enable the ‘Pick-up’ function, which activates the Penthouse floor call button present in the COP. When the Pick-up key is enabled, the system does not alter the operation of the elevator (it does not exclude other cabin or floor calls), as the key can remain active for several hours, for example, in special occasions.
When the system detects activation of the key in the cabin or at the floors programmed with this function, it sends the key pictogram to the displays.
Key location | Type (Position / Extraction) | Input | Contact type |
---|---|---|---|
Cabin | 2P / 1E / Sprin return | DMCPIT >> Spare | Normally closed |

Pick up
Enables the reserved floor, programmable from the controller via the LOP of the reserved floor.
Key location | Type (Position / Extraction) | Input | Contact type |
---|---|---|---|
Floors | 2P / 1E | BDU >> IN-1 CSITLOPV30 >> KEY | Normally open |


Firefighter phase 1
Activates the firefighters operation EN81-72 phase 1
Key location | Type (Position / Extraction) | Input | Contact type |
---|---|---|---|
Floors | 2P / 2E | BDU >> FF KEYS CSITLOPV30 >> S12 | Normally closed |


Firefighter phase 2
Activates the firefighters operation EN81-72 phase 2
Key location | Type (Position / Extraction) | Input | Contact type |
---|---|---|---|
Cabin | 2P / 1E | DMCPIT >> Fireman | Normally closed |

Cabin priority
Clears all calls and disables calls from the floors. Elevator movement is only possible from the cabin control panel.
Key location | Type (Position / Extraction) | Input | Contact type |
---|---|---|---|
Cabin | 2P / 1E | DMCPIT >> Car priority | Normally open |

Floor priority
Clears all calls and disables calls from the cabin. Moves the cabin to the floor where the key activated this function.
Key location | Type (Position / Extraction) | Input | Contact type |
---|---|---|---|
Floors | 2P / 1E / Sprin return | BDU >> IN-1 CSITLOPV30 >> KEY | Normally open |


Cabin ventilation
Turns the cabin ventilation ON and OFF with visual feedback for cabin status. Activates the output on the FAN connector of the TOC box.
Key location | Type (Position / Extraction) | Input | Contact type |
---|---|---|---|
Cabin | 2P / 1E / Sprin return | DMCPIT >> Fan | Normally open |

Floor calls
Makes a floor call via key contact, instead of the button.
Key location | Type (Position / Extraction) | Input | Contact type |
---|---|---|---|
Floors | 2P / 1E / Sprin return | BDU >> P-BUTTON UP BDU >> P-BUTTON DOWN | Normally open |

Evacuation
Activates the evacuation operation EN 81-73.
At the end of the operation, the elevator opens and closes the doors if programmed. The door open button in the cabin must remain active, and in case of a call from a preset floor, the elevator must open and close the doors.
Key location | Type (Position / Extraction) | Input | Contact type |
---|---|---|---|
Floors | 2P / 2E | BDU >> FF KEYS CSITLOPV30 >> S12 | Normally open |


Lift off (Elevator parking out of order)
Clears all floor calls, disables cabin calls, and completes the registered calls. Moves the elevator to the preset floor and parks the elevator with doors closed. The door open button in the cabin must remain active.
Key location | Type (Position / Extraction) | Input | Contact type |
---|---|---|---|
Floors | 2P / 2E | BDU >> IN-2 CSITLOPV30 >> S12 | Normally open |


Pit access reset
Reset pit access according to:
EN 81-20 (§5.2.6.4.4.1 g)
EN 81-21 (§5.5.3.2 and §5.5.3.3)
Key location | Type (Position / Extraction) | Input | Contact type |
---|---|---|---|
Floors | 2P / 1E / Sprin return | BDU >> M1 (CPOR-GND) |

Call to floor Emergency lift
D.M. 15 settembre 2005
A key switch, located on each served floor, must allow the firefighters to directly call the emergency elevator.
Key location | Type (Position / Extraction) | Input | Contact type |
---|---|---|---|
Floors | 2P / 1E / Sprin return | BDU >> FF KEYS | Normally open |