Pitagora 4.0 – Key-switch functions


Call enabling

CABIN

Enables all cabin call buttons simultaneously.

Key locationType (Position / Extraction)InputContact type
Cabin2P / 1EDMCPIT >> Call enableNormally closed

FLOORS

Enables all floors call buttons simultaneously.

Key locationType (Position / Extraction)InputContact type
Floors2P / 1E
2P / 2E
BDU >> IN-1
CSITLOPV30 >> KEY
Normally open

Reset of cabin call requests

Delete all calls

Key locationType (Position / Extraction)InputContact type
Cabin2P / 1E / Sprin returnDMCPIT >> Call cancelNormally open

Cabin calls

Makes a cabin call via key contact, instead of the button.

Key locationType (Position / Extraction)InputContact type
Cabin2P / 1E / Sprin returnDMCPIT >> Call00…Call27Normally open

Penthouse

Enable the reserved floor, programmable from the controller. Solution for systems with direct access to private houses (or private floors), typically on the top floor of the building.

The COP should include one or more keys (depending on the number of protected floors) to make a call to the ‘Penthouse’ floor, and a button for each protected floor, normally disabled, which is activated only by the associated Pick-up key.
In the LOP of the Penthouse floor, a key-switch should be provided to enable the ‘Pick-up’ function, which activates the Penthouse floor call button present in the COP. When the Pick-up key is enabled, the system does not alter the operation of the elevator (it does not exclude other cabin or floor calls), as the key can remain active for several hours, for example, in special occasions.

When the system detects activation of the key in the cabin or at the floors programmed with this function, it sends the key pictogram to the displays.

Key locationType (Position / Extraction)InputContact type
Cabin2P / 1E / Sprin returnDMCPIT >> SpareNormally closed

Pick up

Enables the reserved floor, programmable from the controller via the LOP of the reserved floor.

Key locationType (Position / Extraction)InputContact type
Floors2P / 1EBDU >> IN-1
CSITLOPV30 >> KEY
Normally open

Firefighter phase 1

Activates the firefighters operation EN81-72 phase 1

Key locationType (Position / Extraction)InputContact type
Floors2P / 2EBDU >> FF KEYS
CSITLOPV30 >> S12
Normally closed

Firefighter phase 2

Activates the firefighters operation EN81-72 phase 2

Key locationType (Position / Extraction)InputContact type
Cabin2P / 1EDMCPIT >> FiremanNormally closed

Cabin priority

Clears all calls and disables calls from the floors. Elevator movement is only possible from the cabin control panel.

Key locationType (Position / Extraction)InputContact type
Cabin2P / 1EDMCPIT >> Car priorityNormally open

Floor priority

Clears all calls and disables calls from the cabin. Moves the cabin to the floor where the key activated this function.

Key locationType (Position / Extraction)InputContact type
Floors2P / 1E / Sprin returnBDU >> IN-1
CSITLOPV30 >> KEY
Normally open

Cabin ventilation

Turns the cabin ventilation ON and OFF with visual feedback for cabin status. Activates the output on the FAN connector of the TOC box.

Key locationType (Position / Extraction)InputContact type
Cabin2P / 1E / Sprin returnDMCPIT >> FanNormally open

Floor calls

Makes a floor call via key contact, instead of the button.

Key locationType (Position / Extraction)InputContact type
Floors2P / 1E / Sprin returnBDU >> P-BUTTON UP
BDU >> P-BUTTON DOWN
Normally open

Evacuation

Activates the evacuation operation EN 81-73.
At the end of the operation, the elevator opens and closes the doors if programmed. The door open button in the cabin must remain active, and in case of a call from a preset floor, the elevator must open and close the doors.

Key locationType (Position / Extraction)InputContact type
Floors2P / 2EBDU >> FF KEYS
CSITLOPV30 >> S12
Normally open

Lift off (Elevator parking out of order)

Clears all floor calls, disables cabin calls, and completes the registered calls. Moves the elevator to the preset floor and parks the elevator with doors closed. The door open button in the cabin must remain active.

Key locationType (Position / Extraction)InputContact type
Floors2P / 2EBDU >> IN-2
CSITLOPV30 >> S12
Normally open

Pit access reset

Reset pit access according to:
EN 81-20 (§5.2.6.4.4.1 g)
EN 81-21 (§5.5.3.2 and §5.5.3.3)

Key locationType (Position / Extraction)InputContact type
Floors2P / 1E / Sprin returnBDU >> M1 (CPOR-GND)

Call to floor Emergency lift

D.M. 15 settembre 2005
A key switch, located on each served floor, must allow the firefighters to directly call the emergency elevator.

Key locationType (Position / Extraction)InputContact type
Floors2P / 1E / Sprin returnBDU >> FF KEYSNormally open