1) Switch the system into NORMAL service mode

Main Menu > Emulation > Configuration > Temporary operations > NO

2) System reset

The LED 7 is OFF – There are no active faults.
The cabin moves to the lowest floor for a system reset.


The red LED 7 is flashing – One or more faults are active.
If the system is in final limit, the malfunction may be due to an error during the installation of the position sensors.

The Red LED 7 is lit steady – One or more blocking faults are present for the cabin.
The system is not operating, check the error code in the troubleshooting section.

3) Adjust the stopping accuracy at each floor

If no faults are present, a finer adjustment of the floor stopping accuracy is possible.

4) Perform overall system check

For a quick check of correct installation, refer to the Test and Measurements section.